uPVC AIR - CON TRUNKING

Manufactured from an extra High Impact grade of uPVC, LITAFLEX AIR–CONDITIONING TRUNKING is Fire Resistant rated and complies with the Singapore Standard SS 275: 1999.

To facilitate distribution from the outdoor Air-Conditioning Condensing Unit to the Fan Coil Unit mounted on the wall of the living room, LITAFLEX has intelligently design this non-corrosive Trunking system to secure Electrical Cables, Insulation Tubes containing Copper Tubes and uPVC Drain Pipes.

LITAFLEX's latest NEW design on the Base and 'snap-on' lids provide a stronger grip, easy installation and also the removal for maintenance. The unique characteristics of its clean and smooth curvy edges, strength and durability allow it to be used even on rough wall surfaces and ceilings.

What is more, LITAFLEX's air-conditioning trunking is made of high weather resistant, which ensures a lasting appearance of beauty.

uPVC AIR - CONDITIONING TRUNKING
Product No.External Dimension
Width X Height
Standard Pack
LocalExport
TK 040025
TK 040040
40mm X 25mm
40mm X 40mm
10
10
20
20
TK 050032
TK 050040
TK 050050
50mm X 32mm
50mm X 40mm
50mm X 50mm
10
10
10
20
20
20
TK 075050
TK 075060
TK 075075
75mm X 50mm
75mm X 60mm
75mm X 75mm
5
5
4
10
10
10
TK 085065
TK 105065
85mm X 65mm
105mm X 65mm
4
4
8
8
TK 100050
TK 100060
TK 100080
TK 100100
100mm X 50mm
100mm X 60mm
100mm X 80mm
100mm X 100mm
5
5
4
2
10
10
8
6
TK 125055
TK 125100
125mm X 55mm
125mm X 100mm
5
2
10
6
TK 150080
TK 150100
150mm X 80mm
150mm X 100mm
2
2
6
6
TK 200055
TK 200100
200mm X 55mm
200mm X 100mm
2
2
2
2

STANDARD LENGTH :  2.44M
COLOUR :  WHITE
 
 
BEAUTIFY OUR HOME
Smooth finishing to match interior and exterior of buildings

 

Installation Capacity of Multi Split Unit Air-Conditioning System
lita-1
1 Condensing Unit to 1 Fan Coil
lita-2
Insulated Drain Pipe
lita-3
1 Condensing Unit to 2 Fan Coil


I Condensing Unit to I Fan Coil
Clause Test Required
Mechanical Properties
Cable Supporting Test for surface mounting
Temperature
Duration
Distortion (Max)



60 ± 2°C
2 hr
10%
Impact Test
Precondition
Duration
Test Temperature
Mass of Hammer
Height of Impact

60 ± 2°C
240hr
15°C
2 kg
100 mm
Cover Retention Test
Mass attached to Cover
Duration of Test

2 kg
60 sec
Clause Test Required
Resistant to Heat
Testing Temperature
Applied force of Ball Pressure
Duration of Test
Diameter of impression

60 ± 2°C
20 N
1 hr
< 2 mm
Resistance to Flame Propagation
Flame Test

Does not ignite or flames.
Self extinguished within
30s after removal of flame.
Insulating Characteristics
Electric Insulating Strength Test

Applied Voltage
Duration of Electrication



2500 V
1 min
Insulation Resistance test
Applied Voltage
Duration of Electrification

500 V dc
1 min